Data centre cooling
Hyperscale and colocation data centres run on water: chilled-water mains, condenser loops and, increasingly, liquid cooling straight to the rack. Teshi Group manufactures the flanges, fittings, valves and prefabricated spools for these systems, and supplies the pipe and steel. Every order ships with mill test certificates, dimensional reports and the third-party inspection your project specifies.
Commonly supplied to data centre projects
01OEM manufacturerIndustrial Flanges
NPS ½"–60" · CS / SS / Alloy
02OEM manufacturerButt Weld Fittings
NPS ½"–48" · CS / SS / Alloy
05OEM manufacturerIndustrial Valves
NPS ½"–24" · Cast / Forged
08Stockist & supplierIndustrial Pipes
NPS ⅛"–48" · CS / SS / Alloy
07OEM manufacturerCustom Fabrication
As per drawing · CS / SS / Alloy
06OEM manufacturerFasteners
M10–M64 · ½"–4" · Alloy / SS
Systems we supply
Chilled-water primary & secondary loops
Carbon steel pipe, A234 WPB elbows, tees and reducers, A105 weld neck and slip-on flanges, butterfly and check valves — DN 50 to DN 1200.
Condenser water & cooling towers
Large-bore flanges to ASME B16.47 / AWWA C207, fabricated headers and spools, galvanised or epoxy-lined where specified.
Liquid cooling (CDU and direct-to-chip)
304L / 316L stainless pipe, butt-weld and socket-weld fittings and flanges with clean, pickled and passivated finish for technology cooling loops.
Fire protection
Flanges, fittings and pipe for sprinkler, hydrant and pre-action systems, plus fabricated risers and manifolds.
Generator fuel & exhaust
Carbon steel fuel-oil piping, flanges and valves for diesel generator day tanks, and steel for exhaust and support structures.
Plant-room steel
Steel plates and structural sections for pipe racks, chiller and pump bases, and modular skid frames.
Materials & standards
Materials specified
Carbon steel for chilled and condenser water; 304L / 316L stainless steel for liquid-cooling loops.
FAQ
Data centre piping: common questions
What piping materials are used in data centre cooling systems?
Chilled-water and condenser-water mains are usually carbon steel (A106 / A53 pipe, A234 WPB fittings, A105 flanges), often galvanised or internally lined. Liquid-cooling loops serving coolant distribution units (CDUs) and direct-to-chip racks use 304L or 316L stainless steel for cleanliness and to protect cold plates from corrosion products.
Can Teshi supply prefabricated spools for data centre plant rooms?
Yes. Teshi Group fabricates pipe spools to isometric drawings — chiller headers, pump manifolds and CDU skids — with flanges and fittings manufactured in-house, tested and tagged for fast on-site installation.
Which flange standards do data centre projects use?
ASME B16.5 Class 150 and 300 for pipe up to 24 in, ASME B16.47 or AWWA C207 for large chilled-water mains, and EN 1092-1 PN 10/16 on European-specification projects. Teshi manufactures all of these.
Do you supply valves for chilled-water systems?
Yes — butterfly, gate, globe, check and ball valves in cast and forged bodies for isolation, balancing and non-return duty, plus stud bolts and gaskets for every flanged joint.
Do you export to data centre projects outside India?
Yes. Teshi Group ships worldwide from India with mill test certificates (EN 10204 3.1), dimensional reports and third-party inspection where required.

Ready to build to spec?
Share your P&ID, isometric or bill of materials for a technical review in 24–48 hours.