IS 6392 Plate Flange & Blind Flange Dimensions
This chart gives IS 6392 plate flange (plate flange for welding) and blind flange dimensions in millimetres for every pressure rating from PN 2.5 to PN 160 — outside diameter, bore and plate and blind thickness. IS 6392 is the Indian Standard for steel pipe flanges, used on water, power, steel-plant and process projects across India.
Plate flanges are Teshi Group's core product: cut, machined and drilled in our own works in India from DN 10 up to 8000 NB (8 metres), in carbon, boiler-quality, stainless, duplex and nickel-alloy plate, with EN 10204 3.1 certificates.
Key to dimensions
- D
- Outside diameter of flange
- B
- Bore (inside diameter) of plate flange
- C
- Flange thickness — plate or blind, raised face (RF) or flat face (FF)
IS 6392 Plate Flange & Blind Flange Dimensions — tables
IS 6392 PN 2.5 (Table 3) — plate and blind flange (mm)
| SizeNB | DFlange OD · mm | BBore · mm | CPlate, RF · mm | CBlind, RF · mm |
|---|---|---|---|---|
| 1200 | 1375 | 1222 | 36 | 36 |
| 1400 | 1575 | 1422 | 42 | 42 |
| 1600 | 1790 | 1622 | 46 | 46 |
| 1800 | 1990 | 1822 | 52 | 52 |
| 2000 | 2190 | 2022 | 58 | 58 |
IS 6392 PN 6 (Table 5) — plate and blind flange (mm)
| SizeNB | DFlange OD · mm | BBore · mm | CPlate, RF · mm | CBlind, RF · mm |
|---|---|---|---|---|
| 10 | 75 | 19.2 | 12 | 12 |
| 15 | 80 | 23.3 | 12 | 12 |
| 20 | 90 | 28.9 | 14 | 14 |
| 25 | 100 | 35.7 | 14 | 14 |
| 32 | 120 | 44.4 | 16 | 16 |
| 40 | 130 | 50.3 | 16 | 16 |
| 50 | 140 | 62.3 | 16 | 16 |
| 65 | 160 | 78.1 | 16 | 16 |
| 80 | 190 | 90.9 | 18 | 18 |
| 100 | 210 | 116.3 | 18 | 18 |
| 125 | 240 | 141.7 | 20 | 20 |
| 150 | 265 | 170.3 | 20 | 20 |
| 200 | 320 | 221.1 | 22 | 22 |
| 250 | 375 | 275 | 24 | 24 |
| 300 | 440 | 325.9 | 24 | 24 |
| 350 | 490 | 357.6 | 26 | 26 |
| 400 | 540 | 408.4 | 28 | 28 |
| 500 | 645 | 510 | 30 | 30 |
| 600 | 755 | 611.6 | 32 | 32 |
| 700 | 860 | 713.2 | 34 | 34 |
| 800 | 975 | 814.8 | 38 | 38 |
| 900 | 1075 | 916.4 | 42 | 42 |
| 1000 | 1175 | 1018 | 46 | 46 |
| 1200 | 1405 | 1222 | 56 | 56 |
| 1400 | 1630 | 1422 | 66 | 66 |
| 1600 | 1830 | 1622 | 74 | 74 |
| 1800 | 2045 | 1822 | 84 | 84 |
| 2000 | 2265 | 2022 | 92 | 92 |
IS 6392 PN 10 (Table 11) — plate and blind flange (mm)
| SizeNB | DFlange OD · mm | BBore · mm | CPlate, RF · mm | CBlind, RF · mm |
|---|---|---|---|---|
| 10 | 90 | 19.2 | 14 | 14 |
| 15 | 95 | 23.3 | 14 | 14 |
| 20 | 105 | 28.9 | 16 | 16 |
| 25 | 115 | 35.7 | 16 | 16 |
| 32 | 140 | 44.4 | 16 | 16 |
| 40 | 150 | 50.3 | 16 | 16 |
| 50 | 165 | 62.3 | 18 | 18 |
| 65 | 185 | 78.1 | 18 | 18 |
| 80 | 200 | 90.9 | 20 | 20 |
| 100 | 220 | 116.3 | 20 | 20 |
| 125 | 250 | 141.7 | 22 | 22 |
| 150 | 285 | 170.3 | 22 | 22 |
| 175 | 315 | 195.7 | 24 | 24 |
| 200 | 340 | 221.1 | 24 | 24 |
| 250 | 395 | 275 | 26 | 26 |
| 300 | 445 | 325.9 | 26 | 26 |
| 350 | 505 | 357.6 | 28 | 28 |
| 400 | 565 | 408.4 | 32 | 32 |
| 500 | 670 | 510 | 38 | 38 |
| 600 | 780 | 611.6 | 42 | 42 |
| 700 | 895 | 713.2 | 46 | 46 |
| 800 | 1015 | 814.8 | 52 | 52 |
| 900 | 1115 | 916.4 | 56 | 56 |
| 1000 | 1230 | 1018 | 62 | 62 |
| 1200 | 1455 | 1222 | 74 | 74 |
IS 6392 PN 16 (Table 17) — plate and blind flange (mm)
| SizeNB | DFlange OD · mm | BBore · mm | CPlate, RF · mm | CBlind, RF · mm |
|---|---|---|---|---|
| 10 | 90 | 19.2 | 14 | 14 |
| 15 | 95 | 23.3 | 14 | 14 |
| 20 | 105 | 28.9 | 16 | 16 |
| 25 | 115 | 35.7 | 16 | 16 |
| 32 | 140 | 44.4 | 16 | 16 |
| 40 | 150 | 50.3 | 16 | 16 |
| 50 | 165 | 62.3 | 18 | 18 |
| 65 | 185 | 78.1 | 18 | 18 |
| 80 | 200 | 90.9 | 20 | 20 |
| 100 | 220 | 116.3 | 20 | 20 |
| 125 | 250 | 141.7 | 22 | 22 |
| 150 | 285 | 170.3 | 22 | 22 |
| 175 | 315 | 195.7 | 24 | 24 |
| 200 | 340 | 221.1 | 24 | 24 |
| 250 | 405 | 275 | 26 | 26 |
| 300 | 460 | 325.9 | 28 | 28 |
| 350 | 520 | 357.6 | 32 | 32 |
| 400 | 580 | 408.4 | 36 | 36 |
| 500 | 715 | 510 | 44 | 44 |
| 600 | 840 | 611.6 | 52 | 52 |
| 700 | 910 | 713.2 | 58 | 58 |
| 800 | 1025 | 814.8 | 64 | 64 |
| 900 | 1125 | 916.4 | 72 | 72 |
| 1000 | 1255 | 1018 | 78 | 78 |
| 1200 | 1485 | 1222 | 94 | 94 |
IS 6392 PN 25 (Table 23) — plate and blind flange (mm)
| SizeNB | DFlange OD · mm | BBore · mm | CPlate, RF · mm | CBlind, RF · mm |
|---|---|---|---|---|
| 10 | 90 | 19.2 | 16 | 16 |
| 15 | 95 | 23.3 | 16 | 16 |
| 20 | 105 | 28.9 | 18 | 18 |
| 25 | 115 | 35.7 | 18 | 18 |
| 32 | 140 | 44.4 | 18 | 18 |
| 40 | 150 | 50.3 | 20 | 20 |
| 50 | 165 | 62.3 | 20 | 20 |
| 65 | 185 | 78.1 | 22 | 22 |
| 80 | 200 | 90.9 | 24 | 24 |
| 100 | 235 | 116.3 | 26 | 26 |
| 125 | 270 | 141.7 | 28 | 28 |
| 150 | 300 | 170.3 | 30 | 30 |
| 175 | 330 | 195.7 | 26 | 26 |
| 200 | 360 | 221.1 | 28 | 28 |
| 250 | 425 | 275 | 32 | 32 |
| 300 | 485 | 325.9 | 38 | 38 |
| 350 | 555 | 357.6 | 42 | 42 |
| 400 | 620 | 408.4 | 46 | 46 |
| 500 | 730 | 510 | 58 | 58 |
| 600 | 845 | 611.6 | 66 | 66 |
IS 6392 PN 40 (Table 28) — plate and blind flange (mm)
| SizeNB | DFlange OD · mm | BBore · mm | CPlate, RF · mm | CBlind, RF · mm |
|---|---|---|---|---|
| 10 | 90 | 19.2 | 16 | 16 |
| 15 | 95 | 23.3 | 16 | 16 |
| 20 | 105 | 28.9 | 18 | 18 |
| 25 | 115 | 35.7 | 18 | 18 |
| 32 | 140 | 44.4 | 18 | 18 |
| 40 | 150 | 50.3 | 20 | 20 |
| 50 | 165 | 62.3 | 20 | 20 |
| 65 | 185 | 78.1 | 22 | 22 |
| 80 | 200 | 90.9 | 24 | 24 |
| 100 | 235 | 116.3 | 26 | 26 |
| 125 | 270 | 141.7 | 28 | 28 |
| 150 | 300 | 170.3 | 30 | 30 |
| 175 | 350 | 195.7 | 32 | 32 |
| 200 | 375 | 221.1 | 34 | 34 |
| 250 | 450 | 275 | 42 | 42 |
| 300 | 515 | 325.9 | 50 | 50 |
| 350 | 580 | 357.6 | 56 | 56 |
| 400 | 660 | 408.4 | 64 | 64 |
| 500 | 755 | 510 | 72 | 72 |
IS 6392 PN 64 (Table 34) — plate and blind flange (mm)
| SizeNB | DFlange OD · mm | BBore · mm | CPlate, RF · mm | CBlind, RF · mm |
|---|---|---|---|---|
| 10 | 100 | 19.2 | 20 | 20 |
| 15 | 105 | 23.3 | 20 | 20 |
| 20 | 130 | 28.9 | 22 | 22 |
| 25 | 140 | 35.7 | 24 | 24 |
| 32 | 155 | 44.4 | 24 | 24 |
| 40 | 170 | 50.3 | 26 | 26 |
| 50 | 180 | 62.3 | 26 | 26 |
| 65 | 205 | 78.1 | 26 | 26 |
| 80 | 215 | 90.9 | 30 | 30 |
| 100 | 250 | 116.3 | 32 | 32 |
| 125 | 295 | 141.7 | 34 | 34 |
| 150 | 345 | 170.3 | 36 | 36 |
| 175 | 375 | 195.7 | 40 | 40 |
| 200 | 415 | 221.1 | 46 | 46 |
| 250 | 470 | 275 | 54 | 54 |
| 300 | 530 | 325.9 | 62 | 62 |
| 350 | 600 | 357.6 | 72 | 72 |
| 400 | 670 | 408.4 | 78 | 78 |
IS 6392 PN 100 (Table 38) — plate and blind flange (mm)
| SizeNB | DFlange OD · mm | BBore · mm | CPlate, RF · mm | CBlind, RF · mm |
|---|---|---|---|---|
| 10 | 100 | 19.2 | 20 | 20 |
| 15 | 105 | 23.3 | 20 | 20 |
| 20 | 130 | 28.9 | 22 | 22 |
| 25 | 140 | 35.7 | 24 | 24 |
| 32 | 155 | 44.4 | 24 | 24 |
| 40 | 170 | 50.3 | 26 | 26 |
| 50 | 195 | 62.3 | 28 | 28 |
| 65 | 220 | 78.1 | 30 | 30 |
| 80 | 230 | 90.9 | 34 | 34 |
| 100 | 265 | 116.3 | 36 | 36 |
| 125 | 315 | 141.7 | 42 | 42 |
| 150 | 355 | 170.3 | 48 | 48 |
| 175 | 385 | 195.7 | 54 | 54 |
| 200 | 430 | 221.1 | 60 | 60 |
| 250 | 505 | 275 | 72 | 72 |
| 300 | 585 | 325.9 | 84 | 84 |
| 350 | 655 | 357.6 | 95 | 95 |
| 400 | 715 | 408.4 | 106 | 106 |
| 500 | 870 | 510 | 128 | 128 |
IS 6392 PN 160 (Table 42) — plate and blind flange (mm)
| SizeNB | DFlange OD · mm | BBore · mm | CPlate, RF · mm | CBlind, RF · mm |
|---|---|---|---|---|
| 10 | 100 | 19.2 | 22 | 22 |
| 15 | 105 | 23.3 | 24 | 24 |
| 20 | 130 | 28.9 | 26 | 26 |
| 25 | 140 | 35.7 | 26 | 26 |
| 32 | 155 | 44.4 | 28 | 28 |
| 40 | 170 | 50.3 | 30 | 30 |
| 50 | 195 | 62.3 | 34 | 34 |
| 65 | 220 | 78.1 | 36 | 36 |
| 80 | 230 | 90.9 | 40 | 40 |
| 100 | 265 | 116.3 | 44 | 44 |
| 125 | 315 | 141.7 | 54 | 54 |
| 150 | 355 | 170.3 | 62 | 62 |
| 175 | 390 | 195.7 | 68 | 68 |
| 200 | 430 | 221.1 | 76 | 76 |
| 250 | 515 | 275 | 90 | 90 |
| 300 | 585 | 325.9 | 106 | 106 |
Notes
- All dimensions are in millimetres; sizes are nominal bore (NB / DN).
- Plate flange thickness is given for raised-face (RF) and flat-face (FF) flanges; where only RF is shown, the FF thickness is the same.
- Reference values for estimation and checking. Verify against the current edition of the standard and the purchase specification before design, purchase or fabrication.
Reference information compiled from the published standard for convenience. It does not replace the current edition of the governing standard, which takes precedence. Verify critical dimensions and properties before design, purchase or fabrication. Teshi Engineers & Sales Promoters (P) Ltd accepts no liability for errors or omissions.
FAQ
IS 6392 Plate Flange & Blind Flange dimensions: common questions
Which IS 6392 table is the PN 16 plate flange?
Table 17 (1.6 N/mm²). PN 10 is Table 11, PN 6 is Table 5 and PN 40 is Table 28.
Do IS 6392 flanges mate with EN 1092-1 flanges?
Generally yes for the same PN — IS 6392 follows the ISO/DIN metric drilling — but check the raised face and thickness for your duty.
Related products, data sheets and standards
Slip-On Flange
OEM manufacturer
View online · PDFTechnical data sheetBlind Flange
OEM manufacturer
View online · PDFIS 6392IS 6392 PN 16 flange dimensions
IS 6392 PN 16 plate (slip-on), weld neck and blind flange dimensions in mm: OD, thickness, raised face, PCD and bolting.
View online · PDFIS 6392IS 6392 PN 10 flange dimensions
IS 6392 PN 10 plate (slip-on), weld neck and blind flange dimensions in mm: OD, thickness, raised face, PCD and bolting.
View online · PDFIS 6392IS 6392 PN 6 flange dimensions
IS 6392 PN 6 plate (slip-on), weld neck and blind flange dimensions in mm: OD, thickness, raised face, PCD and bolting.
View online · PDF
Ready to build to spec?
Share your drawing, bill of materials or technical requirements with the Teshi team.