Flange bolt torque calculator
Tightening torque from bolt load or target stress (K-factor method).
How it's calculated. T = K × F × d. K ≈ 0.20 for dry steel, 0.16 lubricated, 0.10–0.12 with PTFE coating. Always follow the gasket maker's and your project's bolting procedure.