IS 6392 — Plate & blind flange — NP16.0 (Table 42)
IS 6392 Plate & blind flange — NP16.0 (Table 42) — 16 sizes.
| Size (NB) | Outside dia (OD) (mm) | Bore / ID (plate) (mm) | Thickness — plate RF (mm) | Thickness — blind RF (mm) | Teshi QC flag |
|---|---|---|---|---|---|
| 10 | 100 | 19.2 | 22 | 22 | STD~ID |
| 15 | 105 | 23.3 | 24 | 24 | STD~ID |
| 20 | 130 | 28.9 | 26 | 26 | STD~ID |
| 25 | 140 | 35.7 | 26 | 26 | STD~ID |
| 32 | 155 | 44.4 | 28 | 28 | STD~ID |
| 40 | 170 | 50.3 | 30 | 30 | STD~ID |
| 50 | 195 | 62.3 | 34 | 34 | STD~ID |
| 65 | 220 | 78.1 | 36 | 36 | STD~ID |
| 80 | 230 | 90.9 | 40 | 40 | STD~ID |
| 100 | 265 | 116.3 | 44 | 44 | STD~ID |
| 125 | 315 | 141.7 | 54 | 54 | STD~ID |
| 150 | 355 | 170.3 | 62 | 62 | STD~ID |
| 175 | 390 | 195.7 | 68 | 68 | STD~ID |
| 200 | 430 | 221.1 | 76 | 76 | STD~ID |
| 250 | 515 | 275 | 90 | 90 | STD~ID |
| 300 | 585 | 325.9 | 106 | 106 | STD~ID |
- Blind rows record ID as [0.0] in source; omitted.
- PLATE FF thickness identical to PLATE thickness for every size; FF column omitted.
- BLIND FF thickness identical to BLIND thickness for every size; FF column omitted.
- Source has no values for: PCD, No. of holes, Hole dia, RF dia, RF height.
- Source StdRegistry tab maps NP16.0 to IS 6392 Table 42.
- Verified flag values are copied from the source: 'STD', 'STD~ID' or 'CHECK'. The source does not define them; 'STD~ID' presumably means standard dimensions with a derived/non-standard ID, and 'CHECK' rows were flagged for review.
- Size column is the NB taken from the source Key (e.g. 'NB150'); 'Size label in source' is the Size cell as typed.