EN 1092-1 — Plate & blind flange — PN40
EN 1092-1 Plate & blind flange — PN40 — 20 sizes.
| Size (NB) | Outside dia (OD) (mm) | Bore / ID (plate) (mm) | Thickness — plate RF (mm) | Thickness — blind RF (mm) | Teshi QC flag |
|---|---|---|---|---|---|
| 10 | 90 | 18 | 14 | 14 | STD |
| 15 | 95 | 22 | 14 | 14 | STD |
| 20 | 105 | 27.5 | 16 | 16 | STD |
| 25 | 115 | 34.5 | 16 | 16 | STD |
| 32 | 140 | 43.5 | 18 | 18 | STD |
| 40 | 150 | 49.5 | 18 | 18 | STD |
| 50 | 165 | 61.5 | 20 | 20 | STD |
| 65 | 185 | 77.5 | 22 | 22 | STD |
| 80 | 200 | 90.5 | 24 | 24 | STD |
| 100 | 235 | 116 | 26 | 26 | STD |
| 125 | 270 | 141.5 | 28 | 28 | STD |
| 150 | 300 | 170.5 | 30 | 30 | STD |
| 200 | 375 | 221.5 | 36 | 36 | STD |
| 250 | 450 | 276.5 | 42 | 42 | STD |
| 300 | 515 | 327.5 | 48 | 48 | STD |
| 350 | 580 | 359.5 | 54 | 54 | STD |
| 400 | 660 | 411 | 60 | 60 | STD |
| 450 | 685 | 462 | 66 | 66 | STD |
| 500 | 755 | 513.5 | 72 | 72 | STD |
| 600 | 890 | 616.5 | 84 | 84 | STD |
- Blind rows record ID as [0.0] in source; omitted.
- PLATE FF thickness identical to PLATE thickness for every size; FF column omitted.
- BLIND FF thickness identical to BLIND thickness for every size; FF column omitted.
- Source has no values for: PCD, No. of holes, Hole dia, RF dia, RF height.
- Verified flag values are copied from the source: 'STD', 'STD~ID' or 'CHECK'. The source does not define them; 'STD~ID' presumably means standard dimensions with a derived/non-standard ID, and 'CHECK' rows were flagged for review.
- Size column is the NB taken from the source Key (e.g. 'NB150'); 'Size label in source' is the Size cell as typed.