Teshi PipeData
Flanges · Plate & blind flange

Plate & blind flange NB 1650 Class D — AWWA C207

Plate & blind flange NB 1650 Class D to AWWA C207: outside dia 2032 mm, bore / id (plate) 1681.2 mm, thickness — plate rf 63.5 mm, thickness — blind rf 105.1 mm.

Dimensions of Plate & blind flange NB 1650 Class D

SymbolDimensionValue
ODOutside dia2032 mm (80.000 in)
·Bore / ID (plate)1681.2 mm (66.189 in)
·Thickness — plate RF63.5 mm (2.500 in)
·Thickness — blind RF105.1 mm (4.138 in)
·Teshi QC flagSTD

SKU TSH-FLANGE-AWWA-C207-CLASS-D-1650 · Standard AWWA C207 · Teshi master data

Purchase description

PLATE & BLIND FLANGE, NB 1650, CLASS D, ASTM A105N, AWWA C207

Available materials: ASTM A105N, ASTM A350 LF2 Cl 1, ASTM A182 F304/304L, ASTM A182 F316/316L, ASTM A182 F11 Cl 2, ASTM A182 F22 Cl 3, ASTM A182 F51 (Duplex), ASTM A182 F53 (Super Duplex), ASTM A694 F52 / F60, IS 2062 E250 (plate).

Notes

Same size, other ratings

Other sizes — Plate & blind flange, Class D

Frequently asked questions

What are the main types of pipe flanges?

Weld neck (WN), slip-on (SO), blind (BL), socket weld (SW), threaded (THD), lap joint (LJ) and plate flanges. Special types include orifice, long weld neck, reducing flanges and spectacle blinds.

When should I use a weld neck flange instead of a slip-on?

Use weld neck flanges for high pressure, high or cycling temperature, and lines with vibration or fatigue loading. The tapered hub and full-penetration butt weld spread stress smoothly. Slip-on flanges are cheaper and easier to align, but their fatigue life is roughly one third of a WN.

What does Class 150, 300 or 600 mean on a flange?

The ASME class is a pressure-rating designation, not a pressure in psi. The allowable pressure depends on the material group and temperature. A Class 150 A105 flange is rated 19.6 bar at 38 °C but 13.8 bar at 200 °C.

Is a 150# flange rated for 150 psi?

No. A Class 150 carbon-steel flange is rated about 285 psi (19.6 bar) at ambient temperature, and about 170 psi (11.7 bar) at 260 °C. The "150" is a class number.