Teshi PipeData
Flanges · Weld Neck

Weld Neck Flange RF 60" Class 150 Series A — ASME B16.47 Series A

Weld Neck Flange RF 60" Class 150 Series A to ASME B16.47 Series A: outside diameter 1855 mm, flange thickness, min 131.8 mm, raised face diameter 1676 mm, raised face height 1.6 mm, bolt circle (pcd) 1759 mm; approx. weight 1184.7 kg.

BXRWOtfYSECTIONn × hFACE VIEW
Weld Neck Flange RF 60" Class 150 Series A — dimension symbols match the table below. © Teshi Group · www.teshigroup.com

Dimensions of Weld Neck Flange RF 60" Class 150 Series A

SymbolDimensionValue
OOutside diameter1855 mm (73.031 in)
tfFlange thickness, min131.8 mm (5.189 in)
RRaised face diameter1676 mm (65.984 in)
fRaised face height1.6 mm (0.063 in)
WBolt circle (PCD)1759 mm (69.252 in)
nNumber of bolt holes52
hBolt hole diameter47.63 mm (1.875 in)
dStud bolt size1-3/4"
YLength through hub238 mm (9.370 in)
XHub diameter at base1559 mm (61.378 in)
AHub diameter at weld1524 mm (60.000 in)
mApproximate weight1184.7 kg (2611.81 lb)

SKU TSH-FLANGE-WN-B1647A-150-60 · Standard ASME B16.47 Series A · weight: Calculated from nominal dimensions, carbon steel (ρ 7850 kg/m³)

Purchase description

FLANGE, WELD NECK, RAISED FACE, 60" (DN 1500), CLASS 150, ASTM A105N, ASME B16.47 SERIES A

Available materials: ASTM A105N, ASTM A350 LF2 Cl 1, ASTM A182 F304/304L, ASTM A182 F316/316L, ASTM A182 F11 Cl 2, ASTM A182 F22 Cl 3, ASTM A182 F51 (Duplex), ASTM A182 F53 (Super Duplex), ASTM A694 F52 / F60, IS 2062 E250 (plate).

Bolting and gasket

52 stud bolts 1-3/4" UNC × 390 mm (15.5") with 104 heavy hex nuts — ASTM A193 B7 studs + A194 2H heavy hex nuts. Gasket: Spiral wound 60" Class 150, ASME B16.20, SS316 + graphite, CS outer ring.

Notes

Same size, other ratings

Other sizes — Weld Neck, Class 150

Frequently asked questions

What are the main types of pipe flanges?

Weld neck (WN), slip-on (SO), blind (BL), socket weld (SW), threaded (THD), lap joint (LJ) and plate flanges. Special types include orifice, long weld neck, reducing flanges and spectacle blinds.

When should I use a weld neck flange instead of a slip-on?

Use weld neck flanges for high pressure, high or cycling temperature, and lines with vibration or fatigue loading. The tapered hub and full-penetration butt weld spread stress smoothly. Slip-on flanges are cheaper and easier to align, but their fatigue life is roughly one third of a WN.

What does Class 150, 300 or 600 mean on a flange?

The ASME class is a pressure-rating designation, not a pressure in psi. The allowable pressure depends on the material group and temperature. A Class 150 A105 flange is rated 19.6 bar at 38 °C but 13.8 bar at 200 °C.

Is a 150# flange rated for 150 psi?

No. A Class 150 carbon-steel flange is rated about 285 psi (19.6 bar) at ambient temperature, and about 170 psi (11.7 bar) at 260 °C. The "150" is a class number.

All piping FAQs →